Abstract :
Visible Light Communication (VLC) utilizes LEDs to transmit data through visible light, offering an alternative
to traditional RF systems. This study develops a model for indoor VLC environments, focusing on key factors such as
illuminance distribution, received power, and signal-to-noise ratio (SNR) in both line-of-sight (LOS) and non-line-of-sight
(NLOS) conditions. The research examines how different transmitter setups—single, four, and five LED configurations—
affect system performance, with particular attention to the bit error rate (BER) for two modulation schemes: On-Off Keying
(OOK) and Quadrature Amplitude Modulation (16-QAM). The findings show that multi-LED setups provide enhanced
reliability, especially in diffuse propagation scenarios common in NLOS environments. Multi-LED configurations deliver
better illuminance distribution and higher SNR, making them suitable for complex indoor environments. However, single-
LED setups offer lower BER at higher SNR levels, demonstrating superior performance for simpler setups where direct
communication paths are available. The study also compares modulation schemes, finding that OOK is more resilient to
noise and achieves lower BER, particularly in single-LED configurations, while 16-QAM offers higher data throughput but
is more susceptible to errors in lower SNR conditions. The trade-offs between wider coverage and increased BER in multi-
LED setups indicate that configuration must be tailored to specific environmental conditions and system goals. This research
contributes to the optimization of VLC systems, suggesting that while multi-LED setups are better suited for complex
environments requiring broader coverage, single-LED configurations are more efficient in simpler scenarios where
minimizing errors is crucial. The study's insights are expected to facilitate the wider adoption of VLC technology,
particularly in secure indoor communication systems where RF signals face challenges like interference and limited
bandwidth.
Keywords :
Visible Light Communication; LED; Line-of-Sight; Non-Line-of-Sight; Modulation
References :
- Dahri, F.A., Umrani, F.A., Baqai, A. and Mangrio, H.B., 2020. Design and implementation of LED–LED indoor visible light communication system. Physical communication, 38, p.100981.
- Zeng, L., O'Brien, D., Le-Minh, H., Lee, K., Jung, D. and Oh, Y., 2008, May. Improvement of date rate by using equalization in an indoor visible light communication system. In 2008 4th IEEE international Conference on Circuits and Systems for Communications (pp. 678-682). IEEE.
- O'Brien, D., Le Minh, H., Zeng, L., Faulkner, G., Lee, K., Jung, D., Oh, Y. and Won, E.T., 2008. Indoor visible light communications: challenges and prospects. Free-Space Laser Communications VIII, 7091, pp.60-68.
- Schmid, S., Richner, T., Mangold, S. and Gross, T.R., 2016, June. EnLighting: An indoor visible light communication system based on networked light bulbs. In 2016 13th Annual IEEE International Conference on Sensing, Communication, and Networking (SECON) (pp. 1-9). IEEE.
- Duan, J., Shi, A. and Liu, Y., 2014, July. A practical indoor visible light communication system. In 2014 9th International Symposium on Communication Systems, Networks & Digital Sign (CSNDSP) (pp. 1170-1175). IEEE.
- Hussein, A.T. and Elmirghani, J.M., 2015, June. Performance evaluation of multi-gigabit indoor visible light communication system. In 2015 20th European Conference on Networks and Optical Communications-(NOC) (pp. 1-6). IEEE.
- Liang, Q., Wang, L., Li, Y. and Liu, M., 2018, October. Plugo: A scalable visible light communication system towards low-cost indoor localization. In 2018 IEEE/RSJ International Conference on Intelligent Robots and Systems (IROS) (pp. 3709-3714). IEEE.
- Juneja, S. and Vashisth, S., 2017, October. Indoor positioning system using visible light communication. In 2017 International Conference on Computing and Communication Technologies for Smart Nation (IC3TSN) (pp. 79-83). IEEE.
- Makvandi, A., Kavian, Y.S. and Namjoo, E., 2021. VLCIoT: design and implementation of a visible light communication system for indoor Internet of Things applications. Applied Optics, 60(36), pp.11094-11103.
- Liu, X., Guo, L. and Wei, X., 2021. Indoor visible light applications for communication, positioning, and security. Wireless Communications and Mobile Computing, 2021(1), p.1730655.
- Younus, S.H., Al-Hameed, A.A., Hussein, A.T., Alresheedi, M.T. and Elmirghani, J.M., 2020, July. Multi-branch transmitter for indoor visible light communication systems. In 2020 22nd International Conference on Transparent Optical Networks (ICTON) (pp. 1-6). IEEE.
- Dixit, V. and Kumar, A., 2020, December. Performance analysis of indoor visible light communication system with angle diversity transmitter. In 2020 IEEE 4th Conference on Information & Communication Technology (CICT) (pp. 1-5). IEEE.
- Lin, S.H., Liu, C., Bao, X. and Wang, J.Y., 2018. Indoor visible light communications: performance evaluation and optimization. EURASIP Journal on Wireless Communications and Networking, 2018, pp.1-12.
- Duan, J., Shi, A. and Liu, Y., 2014, July. A practical indoor visible light communication system. In 2014 9th International Symposium on Communication Systems, Networks & Digital Sign (CSNDSP) (pp. 1170-1175). IEEE.
- Ghosh, D., Chatterjee, S., Kothari, V., Kumar, A., Nair, M. and Lokesh, E., 2019, March. An application of Li-Fi based wireless communication system using visible light communication. In 2019 International Conference on Opto-Electronics and Applied Optics (Optronix) (pp. 1-3). IEEE.
- Ala’F, K., AlFasfous, N., Theodory, R., Giha, S. and Darabkh, K.A., 2019, January. On the effect of light emitting diodes positions on the performance of an indoor visible light communication system. In 2019 IEEE Conference of Russian Young Researchers in Electrical and Electronic Engineering (EIConRus) (pp. 10-14). IEEE.
- Gismalla, M.S., Abdullah, M.F.L., Ahmed, M.S., Mabrouk, W.A., Najib, A.F., Saeid, E., Supa'at, A.S.M. and Das, B., 2021. Design and analysis of different optical attocells deployment models for indoor visible light communication system. International Journal of Integrated Engineering, 13(6), pp.253-264.
- Niaz, M.T., Imdad, F., Kim, S. and Kim, H.S., 2016. Deployment methods of visible light communication lights for energy efficient buildings. Optical Engineering, 55(10), pp.106113-106113.
- Gismalla, M.S., Abdullah, M.F., Niass, M.I., Das, B. and Mabrouk, W.A., 2020. Improve uniformity for an indoor visible light communication system. International Journal of Communication Systems, 33(8), p.e4349.
- Nguyen, H.Q., Choi, J.H., Kang, M., Ghassemlooy, Z., Kim, D.H., Lim, S.K., Kang, T.G. and Lee, C.G., 2010, July. A MATLAB-based simulation program for indoor visible light communication system. In 2010 7th International Symposium on Communication Systems, Networks & Digital Signal Processing (CSNDSP 2010) (pp. 537-541). IEEE.
- Mahfouz, N.E., Fayed, H.A., Abd El Aziz, A. and Aly, M.H., 2018. Improved light uniformity and SNR employing new LED distribution pattern for indoor applications in VLC system. Optical and Quantum Electronics, 50, pp.1-18.
- Manivannan, K., Raja, A.S. and Selvendran, S., 2016. Performance Investigation of Visible Light Communication System Using Optisystem Simulation Tool. International Journal of Microwave & Optical Technology, 11(5).
- Choi, S.I., 2012, July. Analysis of VLC channel based on the shapes of white-light LED lighting. In 2012 Fourth International Conference on Ubiquitous and Future Networks (ICUFN) (pp. 1-5). IEEE.
- Komine, T. and Nakagawa, M., 2004. Fundamental analysis for visible-light communication system using LED lights. IEEE transactions on Consumer Electronics, 50(1), pp.100-107.
- Grubor, J., Randel, S., Langer, K.D. and Walewski, J.W., 2008. Broadband information broadcasting using LED-based interior lighting. Journal of Lightwave technology, 26(24), pp.3883-3892.
Visible Light Communication (VLC) utilizes LEDs to transmit data through visible light, offering an alternative
to traditional RF systems. This study develops a model for indoor VLC environments, focusing on key factors such as
illuminance distribution, received power, and signal-to-noise ratio (SNR) in both line-of-sight (LOS) and non-line-of-sight
(NLOS) conditions. The research examines how different transmitter setups—single, four, and five LED configurations—
affect system performance, with particular attention to the bit error rate (BER) for two modulation schemes: On-Off Keying
(OOK) and Quadrature Amplitude Modulation (16-QAM). The findings show that multi-LED setups provide enhanced
reliability, especially in diffuse propagation scenarios common in NLOS environments. Multi-LED configurations deliver
better illuminance distribution and higher SNR, making them suitable for complex indoor environments. However, single-
LED setups offer lower BER at higher SNR levels, demonstrating superior performance for simpler setups where direct
communication paths are available. The study also compares modulation schemes, finding that OOK is more resilient to
noise and achieves lower BER, particularly in single-LED configurations, while 16-QAM offers higher data throughput but
is more susceptible to errors in lower SNR conditions. The trade-offs between wider coverage and increased BER in multi-
LED setups indicate that configuration must be tailored to specific environmental conditions and system goals. This research
contributes to the optimization of VLC systems, suggesting that while multi-LED setups are better suited for complex
environments requiring broader coverage, single-LED configurations are more efficient in simpler scenarios where
minimizing errors is crucial. The study's insights are expected to facilitate the wider adoption of VLC technology,
particularly in secure indoor communication systems where RF signals face challenges like interference and limited
bandwidth.
Keywords :