UV Spectrophotometric Method Development and Validation of Paracetamol, Ambroxol Hydrochloride, Levocetirizine Dihydrochloride, Pseudoephedrine Hydrochloride in Bulk and in Formulation


Authors : Dr. D. Nagavalli; P. Ponguzhali; P. Nanthagopal

Volume/Issue : Volume 8 - 2023, Issue 7 - July

Google Scholar : https://bit.ly/3TmGbDi

Scribd : https://tinyurl.com/mrzrbhz7

DOI : https://doi.org/10.5281/zenodo.8276134

Abstract : For the simultaneous quantification of paracetamol, ambroxol hydrochloride, levocetirizine dihydrochloride, and pseudoephedrine hydrochloride in tablet dosage forms, a simple, specific, accurate, exact, and cost-effective UV-method was devised. The analysis was carried out using Cramer's rule and Gauss-Jorden elimination using UV-spectroscopy of paracetamol, ambroxol hydrochloride, levocetirizine dihydrochloride, and pseudoephedrine hydrochloride as the solvent. The absorbtion maximums for the four drugs of 243, 220, 264, and 257 nm were selected wavelenth. With a regression coefficient of 0.999, a linear response between (12ug-72ug/ml) was seen, and the percentage R.S.D. values of 0.7073, 0.6484, 1.6358, and 0.7308 fall within acceptable bounds. Method was approved in accordance with ICH recommendations.

Keywords : Paracetamol, Ambroxol Hydrochloride, Levocetirizine Dihydrochloride, Pseudoephedrine Hydrochloride, UV-Method.

For the simultaneous quantification of paracetamol, ambroxol hydrochloride, levocetirizine dihydrochloride, and pseudoephedrine hydrochloride in tablet dosage forms, a simple, specific, accurate, exact, and cost-effective UV-method was devised. The analysis was carried out using Cramer's rule and Gauss-Jorden elimination using UV-spectroscopy of paracetamol, ambroxol hydrochloride, levocetirizine dihydrochloride, and pseudoephedrine hydrochloride as the solvent. The absorbtion maximums for the four drugs of 243, 220, 264, and 257 nm were selected wavelenth. With a regression coefficient of 0.999, a linear response between (12ug-72ug/ml) was seen, and the percentage R.S.D. values of 0.7073, 0.6484, 1.6358, and 0.7308 fall within acceptable bounds. Method was approved in accordance with ICH recommendations.

Keywords : Paracetamol, Ambroxol Hydrochloride, Levocetirizine Dihydrochloride, Pseudoephedrine Hydrochloride, UV-Method.

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe