Authors :
Mohammed S. Bahabri; Omar M. Amoudi; Esam H. Mehmadi
Volume/Issue :
Volume 10 - 2025, Issue 1 - January
Google Scholar :
https://tinyurl.com/3wd3eh5s
Scribd :
https://tinyurl.com/4uspet4s
DOI :
https://doi.org/10.5281/zenodo.14869980
Abstract :
This article presents the modulation accuracy analysis for the Tetra Base Station using the Aeroflex 3920 test
equipment. The analysis shows that the modulation accuracy results are in compliance with the specifications of ETSI EN 300
392-2 Terrestrial Trunked Radio (TETRA) [1] Voice plus Data (V+D) Part 2 for Air Interface (AI) which is one of the
industrial standards used as reference for mobile and fixed radio system.
References :
- ETSI EN 300 392-2 Terrestrial Trunked Radio (TETRA) Voice plus Data (V+D) Part 2 for Air Interface (AI) Conformance Testing Specifications
- ETSI European Telecommunications Standards Institute
3. https://en.wikipedia.org/wiki/Error_vector_magnitude
This article presents the modulation accuracy analysis for the Tetra Base Station using the Aeroflex 3920 test
equipment. The analysis shows that the modulation accuracy results are in compliance with the specifications of ETSI EN 300
392-2 Terrestrial Trunked Radio (TETRA) [1] Voice plus Data (V+D) Part 2 for Air Interface (AI) which is one of the
industrial standards used as reference for mobile and fixed radio system.