Retrieval of Separated Endodontic Instrument


Authors : Dr. Kalpana Pawar; Dr. Komal Poltode; Dr. Sadashiv Daokar; Dr. Aishwaoya Ranjalkar; Dr. Renu Asotekar

Volume/Issue : Volume 9 - 2024, Issue 7 - July


Google Scholar : https://tinyurl.com/bddrv7uh

Scribd : https://shorturl.at/UMveq

DOI : https://doi.org/10.38124/ijisrt/IJISRT24JUL1533

Note : A published paper may take 4-5 working days from the publication date to appear in PlumX Metrics, Semantic Scholar, and ResearchGate.


Abstract : Endodontic instrument fracture is a procedural error that creates a significant barrier to routine root canal therapy. A separated instrument results in insufficient cleaning and shaping of the root canals. Inadequate biomechanical preparation has an impact on the result and outcome of root canal treatment. Therefore, retrieval of separated instruments should be considered important. There are many instrument retrieval kits and techniques available for this purpose. In this case report, a separated rotary file was successfully retrieved using a Masserann kit .

References :

  1. Arcangelo CM, Varvara G, Fazio PD. Broken instrument removal two cases. J Endod. 2000;26:568–70.
  2. Roda RS, Gettleman BH. Nonsurgical retreatment. In: Roda RS, Gettleman BH, editors. Pathways of the pulp. 9th ed. St. Louis: CV Mosby; 2006. pp. 982–90.
  3. Sattapan B, Nervo GJ, Palamara JE, Messer HH. Defects in rotary nickel-titanium files after clinical use. J Endod. 2000. March; 26 (3): 161– 5.
  4. Parashos P, Messer HH. Rotary NiTi instrument fracture and its consequences. J Endod. 2006. November; 32 (11): 1031– 43.
  5. Ward JR, Parashos P, Messer HH. Evaluation of an ultrasonic technique to remove fractured rotary nickel-titanium endodontic instruments from root canals: an experimental study. J Endod. 2003. November; 29 (11): 756– 63.
  6. Hulsmann M. Methods for removing metal obstruction from the root canal. Endod Dent Traumatol. 1993;9:223–37.
  7. IqbalMK,KohliMR,KimJS.Aretrospective clinicalstudyofincidenceofrootcanalinstrumentseparation in an endodontics graduate program: a PennEndo database study. JEndod 2006;32:1048-1052.
  8. PengB,ShenY,CheungGS,XiaTJ.Defectsin ProTaperS1instrumentsafterclinicaluse:longitu­dinal examination. IntEndodJ 2005; 38: 550-557
  9. GundayM,SazakH,GaripY.Acomparativestudyof three different root canal curvature measure­ment techniques and measuring the canal access angle in curved canals. JEndod 2005;31:796-798.
  10. Patino P V, Biedma B M, Liebana C R, Cantatore G,Bahillo J G. The influence of a manual glide pathon the separation rate of NiTi rotary instruments.JEndod2005;31:114-116.
  11. Booth J R, Scheetz J P, Lemons J E, Eleazer P D. Acomparison of torque required to fracture three different nickel-titanium rotary instruments around curves of the same angle but of different radiuswhen bound at the tip. JEndod2003;29:55-57.
  12. Grossman LI. Guidelines for the prevention of fracture of root canal instruments. Oral Surg Oral Med Oral Pathol1969;28:746-752.
  13. SattapanB,PalamaraJE,MesserHH.Torque during canal instrumentation using rotary nickel­ titanium files. JEndod 2000; 26: 156-160.
  14. MartinB,ZeladaG,VarelaP,BahilloJGetal.Factors influencing the fractureof nickel­ titanium rotary instruments. IntEndodJ2003;36:262-266.
  15. Guilford W L, Lemons J E, Eleazer P D. A compari­sonoftorquerequiredtofracturerotaryfileswith tipsboundinsimulatedcurvedcanal.JEndod 2005; 31: 468-470.
  16. Wolcott J, Himel V T. Torsional properties of nickel­ titanium versus stainless steel endodontic files. JEndod1997;23:217-220.
  17. MartinB,ZeladaG,VarelaP,BahilloJGetal.Factors influencing the fractureof nickel­ titanium rotary instruments. IntEndodJ2003;36:262-266.
  18. Li U M, Lee B S, Shih C T, Lan W H, Lin C P. Cyclic fatigue of endodontic nickel titanium rotary instruments: static and dynamic tests. JEndod2002; 28: 448-451.
  19. Karagoz-Kucukay I, Ersev H, Engin-Akkoca E, Kucukay S, Gursoy T. Effect of rotational speed onroot canal preparation with Hero 642 rotary Ni-Ti instruments. J Endod 2003; 29: 447-449.
  20. SchraderC,PetersOA.Analysisoftorqueand forcewithdifferentlytaperedrotaryendodonticinstruments invitro.JEndod2005; 31: 120-123.
  21. Walsch H. The hybrid concept of nickel-titaniumrotary instrumentation. DentClinNorthAm 2004;48:183-202.

Endodontic instrument fracture is a procedural error that creates a significant barrier to routine root canal therapy. A separated instrument results in insufficient cleaning and shaping of the root canals. Inadequate biomechanical preparation has an impact on the result and outcome of root canal treatment. Therefore, retrieval of separated instruments should be considered important. There are many instrument retrieval kits and techniques available for this purpose. In this case report, a separated rotary file was successfully retrieved using a Masserann kit .

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe