Replacing Missing Teeth with Screw-Cement Retained Implant Supported Fixed Partial Denture: A Case Report


Authors : Dr. Rahul Bhattacharjee; Dr. Mithun Upadhya; Dr. Vidya K Shenoy; Dr. Glynis Anita Miranda

Volume/Issue : Volume 9 - 2024, Issue 8 - August

Google Scholar : https://tinyurl.com/yfejtrj9

Scribd : https://tinyurl.com/yxb4t6px

DOI : https://doi.org/10.38124/ijisrt/IJISRT24AUG114

Abstract : An accurate impression with proper interocclusal relationship are the two essential criteria used for the best fit and functionality of the final prosthesis when replacing a partly edentulous arch with an implant-supported fixed partial denture. A detailed process about the open tray impression technique and registering the interocclusal relationship for implant- supported partial denture has been described in this case report.

Keywords : Implant Impression, Implant Supported Fixed Partial Denture, Open Tray Impression Technique, Maxilla- Mandibular Relationship.

References :

  1. Stamoulis K. Intraoral registration coping formation using an interim restoration as a matrix. J Prosthodont. 2010;19:406–408.
  2.  Stamoulis K. Intraoral acrylic resin coping fabrication for making interocclusal records. J Prosthodont. 2009;18:184–187.
  3. Ntounis A, Pelekanos S. Custom copings for accurate impressions of multiple internal connection implants. Implant Dent. 2010;19:365–369
  4. Ghazal M, Albashaireh ZS, Kern M. The ability of different materials to reproduce accurate records of interocclusal relation- ships in the vertical dimension. J Oral Rehabil. 2008;35:816–820.
  5. Wood MR, Vermilyea SG. A review of selected dental literature on evidence-based treatment planning for dental implants: report of the Committee on Research in Fixed Prosthodontics of the Academy of Fixed Prosthodontics. J Prosthet Dent. 2004;92:447–462.
  6. Ghazal M, Albashaireh ZS, Kern M. The ability of different materials to reproduce accurate records of interocclusal relation- ships in the vertical dimension. J Oral Rehabil. 2008;35:816–820.
  7. Ntounis A, Pelekanos S. Custom copings for accurate impressions of multiple internal connection implants. Implant Dent. 2010;19:365–369.

An accurate impression with proper interocclusal relationship are the two essential criteria used for the best fit and functionality of the final prosthesis when replacing a partly edentulous arch with an implant-supported fixed partial denture. A detailed process about the open tray impression technique and registering the interocclusal relationship for implant- supported partial denture has been described in this case report.

Keywords : Implant Impression, Implant Supported Fixed Partial Denture, Open Tray Impression Technique, Maxilla- Mandibular Relationship.

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe