Abstract :
Magnetic resonance imaging (MRI) is a vital non-ionizing imaging technology at the forefront of neurological, musculoskeletal, abdominal, cardiovascular, and oncological care. The MRI setting may present unique challenges to claustrophobic patients: the restricted space, the unfamiliar sound, the need to lie still, the procedure length, and the test uncertainty can cause distress. Such stress can result in patient movement, acquisition cancellation, and patient cancellation with adverse effects on costs and diagnostic delays. Improving tolerance to the MRI environment is a patient-centric concern. This article describes factors contributing to claustrophobia and methods to optimize the patient’s co-operation during MRI. Particular attention is paid to pre-MRI screening, education and communication, relaxation techniques, music and video, scanner options, and medication. The MRI technologist has an ideal position to reduce distress by building a therapeutic alliance and encouraging patient participation. Other approaches, which include virtual reality, silent MRI, AI-based image protocol optimization, and patient-focused MRI settings, represent new frontiers in the prevention of claustrophobia.
Keywords :
Magnetic Resonance Imaging; MRI Safety; Claustrophobia; Anxiety; Patient Compliance; Wide-Bore Magnetic Resonance Imaging; Open MRI; Patient-Centered Care.
References :
- Eshed I, Althoff CE, Hamm B, Hermann K-GA. Claustrophobia and premature termination of magnetic resonance imaging examinations. J Magn Reson Imaging. 2007;26(2):401-4. doi:10.1002/jmri.21012.
- Enders J, Zimmermann E, Rief M, Martus P, Klingebiel R, Asbach P, et al. Reduction of claustrophobia with short-bore versus open magnetic resonance imaging: a randomized controlled trial. PLoS One. 2011;6(8):e23494. doi:10.1371/journal.pone.0023494.
- Nieto Alvarez I, Madl J, Becker L, Amft O. Patients' Experience to MRI Examinations-A Systematic Qualitative Review With Meta-Synthesis. J Magn Reson Imaging. 2025 Jan;61(1):480-493. doi: 10.1002/jmri.29365. Epub 2024 Mar 27. PMID: 38544326; PMCID: PMC11645497.
- Lawal O, Regelous P, Omiyi D. Supporting claustrophobic patients during magnetic resonance imaging examination—the patient perspective. Radiography (Lond). 2023;29(6):1108-14. doi:10.1016/j.radi.2023.09.008.
- Tazegul G, Etcioglu E, Yildiz F, Yildiz R, Tuney D. Can MRI related patient anxiety be prevented? Magn Reson Imaging. 2015;33(1):180-3. doi:10.1016/j.mri.2014.08.024.
- Stanley E, Cradock A, Bisset J, McEntee C, O'Connell MJ. Impact of sensory design interventions on image quality, patient anxiety and overall patient experience at MRI. Br J Radiol. 2016;89(1067):20160389. doi:10.1259/bjr.20160389.
- Radomsky AS, Rachman S, Thordarson DS, McIsaac HK, Teachman BA. The Claustrophobia Questionnaire. J Anxiety Disord. 2001 Jul-Aug;15(4):287-97. doi: 10.1016/s0887-6185(01)00064-0
- Spitzer RL, Kroenke K, Williams JB, Löwe B. A brief measure for assessing generalized anxiety disorder: the GAD Arch Intern Med. 2006 May 22;166(10):1092-7. doi: 10.1001/archinte.166.10.1092
- Li R, Wang Y, Wang Z, Baobaid MF. Managing claustrophobia in MRI examination: a mini review. Glob J Public Health Med. 2026;8(1):10-21. doi: 10.37557/h7rphq82
- Murphy KJ, Brunberg JA. Adult claustrophobia, anxiety and sedation in MRI. Magn Reson Imaging. 1997;15(1):51-4.
- American College of Radiology. ACR manual on MR safety. Reston (VA): American College of Radiology; 2026.
Magnetic resonance imaging (MRI) is a vital non-ionizing imaging technology at the forefront of neurological, musculoskeletal, abdominal, cardiovascular, and oncological care. The MRI setting may present unique challenges to claustrophobic patients: the restricted space, the unfamiliar sound, the need to lie still, the procedure length, and the test uncertainty can cause distress. Such stress can result in patient movement, acquisition cancellation, and patient cancellation with adverse effects on costs and diagnostic delays. Improving tolerance to the MRI environment is a patient-centric concern. This article describes factors contributing to claustrophobia and methods to optimize the patient’s co-operation during MRI. Particular attention is paid to pre-MRI screening, education and communication, relaxation techniques, music and video, scanner options, and medication. The MRI technologist has an ideal position to reduce distress by building a therapeutic alliance and encouraging patient participation. Other approaches, which include virtual reality, silent MRI, AI-based image protocol optimization, and patient-focused MRI settings, represent new frontiers in the prevention of claustrophobia.