Development of Computed Tomography Quality Control Training Application Model Based on the American College of Radiology Phantom Integrated Website


Authors : Rudy Harnanto; Kusworo Adi; Dartini

Volume/Issue : Volume 9 - 2024, Issue 8 - August

Google Scholar : https://shorturl.at/WtpJp

Scribd : https://shorturl.at/Au42u

DOI : https://doi.org/10.38124/ijisrt/IJISRT24AUG1017

Abstract : The use of Viewdex as a radiographic image evaluation tool has limited flexibility for students, especially in the complicated process of installation and input of DICOM ACR image results. These limitations can slow down the learning process and reduce the effectiveness of education on radiological image evaluation. This research aims to develop a web-integrated ACR Phantom-based CT quality control training application, which can overcome the weaknesses of Viewdex and improve efficiency and user experience. The research method used is Research and Development (R&D), which consists of several stages: literature study, product development, field testing, evaluation, and product revision. The application developed simplifies the process of DICOM data import, question coding, and automatic evaluation, improving operational efficiency. Validation of information technology and QA/QC experts shows that the application meets high standards in various aspects with 100% validity. Performance evaluation through pre-test and post-test showed a significant improvement in participants' knowledge and skills, with the Wilcoxon test showing a p-value of 0.005. The developed application has proven to be effective and efficient in improving the usability and learning experience of students, overcoming the weaknesses of Viewdex. Its advanced features enable efficient storage, retrieval, and management of medical images, as well as access and analysis of medical data.

Keywords : Viewdex, radiographic image evaluation, ACR Phantom, CT quality control, web application, DICOM, PACS, Research and Development.

References :

  1. Wibowo GM, Fahkruddin F, Rustono R, Khafid M. Training Evaluation Management Model of CT and MRI Quality Control Based on The ACR Phantom Using View Dex Administrator. 2022;1294–301.
  2. Bushberg JT. The Essential Physics of Medical Imaging, Second Edition. philadelpia, USA: Liippincott Williams & Wilkins; 2012.
  3. Middleton W. ACR Acreditation Program/Testing Instruction. 2017.
  4. Soekidjo Notoatmodjo. Pdf-Metodologi-Penelitian-Kesehatan-Notoatmodjo_Compress.Pdf. 2018.
  5. Cantatore A, Müller P. Introduction to computed tomography. 2011.
  6. Bushberg JT. The Essential Physics of Medical Imaging, Second Edition. philadelpia, USA: Liippincott Williams & Wilkins; 2012.
  7. Organization WH. Diagnostic Imaging. 2017;
  8. Dyah. Metode Penelitian Pendidikan Matematika. Metode Penelitian Pendidikan Matematika. 2018. 15–16 p.
  9. Manual QC. Magnetic Resonance Imaging Radiologist ’ s Section. 2015;
  10. Middleton W. ACR Acreditation Program/Testing Instruction. 2017.
  11. Sturm R, Pollard C, Craig J. Managing Web-Based Applications. Application Performance Management (APM) in the Digital Enterprise. 2017;83–93.
  12. Suryawinata OM. Buku Ajar Mata Kuliah Pengembangan Aplikasi Berbasis Web Diterbitkan oleh UMSIDA PRESS. 2019.
  13. Nugraha Et all. Penerapan Metode Sdlc Waterfall Dalam Sistem Informasi Inventori Barang Berbasis Desktop. JUSIM (Jurnal Sistem Informasi Musirawas). 2018;3(1):22–8..
  14. Hanafi. The Concept of Research in Education. Routledge Library Editions: Philosophy of Education: 21 Volume Set. 2022;21(1989):137–53.

The use of Viewdex as a radiographic image evaluation tool has limited flexibility for students, especially in the complicated process of installation and input of DICOM ACR image results. These limitations can slow down the learning process and reduce the effectiveness of education on radiological image evaluation. This research aims to develop a web-integrated ACR Phantom-based CT quality control training application, which can overcome the weaknesses of Viewdex and improve efficiency and user experience. The research method used is Research and Development (R&D), which consists of several stages: literature study, product development, field testing, evaluation, and product revision. The application developed simplifies the process of DICOM data import, question coding, and automatic evaluation, improving operational efficiency. Validation of information technology and QA/QC experts shows that the application meets high standards in various aspects with 100% validity. Performance evaluation through pre-test and post-test showed a significant improvement in participants' knowledge and skills, with the Wilcoxon test showing a p-value of 0.005. The developed application has proven to be effective and efficient in improving the usability and learning experience of students, overcoming the weaknesses of Viewdex. Its advanced features enable efficient storage, retrieval, and management of medical images, as well as access and analysis of medical data.

Keywords : Viewdex, radiographic image evaluation, ACR Phantom, CT quality control, web application, DICOM, PACS, Research and Development.

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe