Authors :
Dr. Tusheel Chowdhury; Dr. Nitesh Rai; Dr. Ponnanna A. A.; Dr. Muralidhar G.; Dr. Ranganatha Rao K. Jingade; Dr. Manasvini N.
Volume/Issue :
Volume 11 - 2026, Issue 11 - November
Google Scholar :
https://tinyurl.com/4tb3uzsu
DOI :
https://doi.org/10.38124/ijisrt/26nov671
Note : A published paper may take 4-5
working days from the publication date to appear in PlumX Metrics, Semantic Scholar, and
ResearchGate.
Abstract :
Background: Mandibular implant-retained overdentures improve prosthetic stability, but the effect of bicortical implant anchorage on stress transfer remains incompletely characterized. This study compared the biomechanical behaviour of monocortically and bicortically anchored implants supporting a mandibular overdenture.
Keywords :
Bicortical Anchorage; Finite Element Analysis; Implant Biomechanics; Mandibular Overdenture; Monocortical Anchorage; Stress Distribution.
References :
- Brånemark PI, Hansson BO, Adell R, Breine U, Lindström J, Hallén O, Ohman A. Osseointegrated implants in the treatment of the edentulous jaw: experience from a 10-year period. Scand J Plast Reconstr Surg Suppl. 1977;16:1–132.
- Adell R, Lekholm U, Rockler B, Brånemark PI. A 15-year study of osseointegrated implants in the treatment of the edentulous jaw. Int J Oral Surg. 1981;10(6):387–416.
- Lekholm U, Zarb GA. Patient selection and preparation. In: Brånemark PI, Zarb GA, Albrektsson T, editors. Tissue-integrated prostheses. Chicago: Quintessence; 1985. p. 199–209.
- Albrektsson T, Zarb G, Worthington P, Eriksson AR. The long-term efficacy of dental implants. Int J Oral Maxillofac Implants. 1986;1(1):11–25.
- Van Waas MAJ. The influence of clinical variables on patients’ satisfaction with complete dentures. J Prosthet Dent. 1990;63(3):307–310.
- Misch CE. Contemporary implant dentistry. 2nd ed. St Louis: Mosby; 1999.
- Mericske-Stern R, Taylor TD, Belser U. Management of edentulous patients. Clin Oral Implants Res. 2000;11(Suppl 1):108–125.
- Geng JP, Tan KBC, Liu GR. Application of finite element analysis in implant dentistry. J Prosthet Dent. 2001;85(6):585–598.
- Sadowsky SJ. Mandibular implant-retained overdentures. J Prosthet Dent. 2001;86(5):468–473.
- Chun HJ, Cheong SY, Han JH, Heo SJ, Chung JP, Rhyu IC, et al. Evaluation of implant design parameters. Clin Oral Implants Res. 2002;13(6):611–620.
- Cune MS, de Putter C, Hoogstraten J. Treatment outcome with implant overdentures. J Prosthet Dent. 2005;93(6):511–518.
- Feine JS, Dufresne E, Boudrias P, Lund JP. Outcome assessment of implant-supported prostheses. J Prosthet Dent. 1998;79(6):628–633.
- Doundoulakis JH, Eckert SE, Lindquist CC, Jeffcoat MK. Implant-supported overdentures. J Am Dent Assoc. 2003;134(11):1455–1458.
- McGill Consensus Statement. Mandibular two-implant overdentures. Int J Prosthodont. 2002;15(4):413–414.
- Schwarz F, Herten M, Bieling K, Becker J. Implant surface characteristics and osseointegration. Clin Oral Implants Res. 2007;18(3):321–328.
- Baggi L, Cappelloni I, Di Girolamo M, Maceri F, Vairo G. Influence of implant diameter and length. Clin Oral Implants Res. 2008;19(7):707–715.
- Sotto-Maior BS, Senna PM, Silva WJ, Del Bel Cury AA. Stress distribution in overdentures. J Prosthet Dent. 2012;108(1):42–50.
- Elias CN, Rocha FA, Nascimento AL, Coelho PG. Implant design and primary stability. J Mech Behav Biomed Mater. 2012;16:169–180.
- Alqutaibi AY, Kaddah AF. Attachment systems for overdentures. J Prosthodont. 2016;25(6):488–495.
- Elsyad MA, Denewar BA, Elsaih EA. Locator vs other attachments. Int J Oral Maxillofac Implants. 2016;31(5):e56–e66.
- Passia N, Ghazal M, Kern M. Long-term retention of attachment systems. Clin Oral Implants Res. 2018;29(Suppl 16):124–137.
- Unsal GS, Erbasar GHN, Aykent F, Ozyilmaz OY, Ozdogan MS. Stress distribution with different bone heights. J Prosthet Dent. 2019;121(4):640–646.
- Alqahtani F, Al-Amri M, Kattadiyil MT, Al-Bishri A. Locator-retained overdentures: finite element analysis. J Prosthet Dent. 2019;121(4):674–681.
- Ye M, Liu W, Cheng S, Yan L. Immediate versus conventional loading. J Oral Implantol. 2020;46(6):549–556.
- Schuster AJ, Possebon APR, Marcello-Machado RM, Chagas-Júnior OL, Faot F. Masticatory function and quality of life. Clin Oral Implants Res. 2020;31(7):627–637.
- Kohli N, Stoddart JC, van Arkel RJ. Micromotion and osseointegration. Sci Rep. 2021;11:10799.
- Mourad KE, Emera RMK, Habib A. Implant position and bone loss. Clin Implant Dent Relat Res. 2024;26(1):45–54.
- Turker N, Buyukkaplan US. Attachment systems stress analysis. J Prosthet Dent. 2011;105(6):386–393.
- Patil PG, Seow LL, Uddanwadikar RV, Ukey PD. Biomechanical behavior of overdentures. J Prosthodont. 2014;23(2):147–152.
- Wang K, Li D, Guo J, Liu B, Shi S. Bicortical anchorage and stability. J Oral Rehabil. 2009;36(6):443–450.
- Pierrisnard L, Renouard F, Renault P, Barquins M. Implant length and bicortical anchorage. Clin Oral Implants Res. 2003;14(3):255–262.
- Lofaj F, Kučera J, Németh D, Kvetková L. Mono vs bicortical implants: finite element analysis. Comput Methods Biomech Biomed Engin. 2015;18(7):725–733.
- Verri FR, Santiago Júnior JF, Almeida DA, Verri AC, Batista VE, Lemos CAA, et al. Bone anchorage comparison. J Prosthet Dent. 2015;114(1):67–76.
- Aydin T, Korkmaz IH, Sahin AB, Kaymaz I. Investigation of subcrestally placed dental implants with and without apical cortical bone anchorage under conventional or immediate loading. Med Eng Phys. 2013;35(9):1387–1393.
- Javed F, Romanos GE. Primary stability and immediate loading. J Dent. 2010;38(8):612–620.
Background: Mandibular implant-retained overdentures improve prosthetic stability, but the effect of bicortical implant anchorage on stress transfer remains incompletely characterized. This study compared the biomechanical behaviour of monocortically and bicortically anchored implants supporting a mandibular overdenture.
Keywords :
Bicortical Anchorage; Finite Element Analysis; Implant Biomechanics; Mandibular Overdenture; Monocortical Anchorage; Stress Distribution.