⚠ Official Notice: www.ijisrt.com is the official website of the International Journal of Innovative Science and Research Technology (IJISRT) Journal for research paper submission and publication. Please beware of fake or duplicate websites using the IJISRT name.



Comparative Evaluation of the Load–Deflection Characteristics of Commercially Available Copper–Nickel–Titanium Orthodontic Archwires: An in Vitro Study


Authors : Dr. Kajal Agarwal; Dr. Chandrashekar B. S.; Dr. Vinay P. Reddy; Dr. Nishan Ansari

Volume/Issue : Volume 11 - 2026, Issue 11 - November


Google Scholar : https://tinyurl.com/m73emskv

DOI : https://doi.org/10.38124/ijisrt/26nov577

Note : A published paper may take 4-5 working days from the publication date to appear in PlumX Metrics, Semantic Scholar, and ResearchGate.


Abstract : Background: Copper–nickel–titanium (CuNiTi) archwires are widely used during orthodontic alignment because of their superelastic behaviour and favourable force delivery. However, wires with identical nominal dimensions may show substantial differences in mechanical performance. This study evaluated and compared the load–deflection characteristics of six commercially available CuNiTi archwires in 0.014-inch round and 0.014 × 0.025-inch rectangular dimensions.

Keywords : Copper–Nickel–Titanium; CuNiTi; Orthodontic Archwire; Load–Deflection; Three-Point Bending; Superelasticity; Mechanical Properties).

References :

  1. Kapila S, Sachdeva R. Mechanical properties and clinical applications of orthodontic wires. Am J Orthod. 1989;96(2):100–109.
  2. Andreasen GF, Hilleman TB. An evaluation of 55 cobalt substituted Nitinol wire for use in orthodontics. J Am Dent Assoc. 1971;82(6):1373–1375.
  3. Alcaraz I, Moyano J, Pàmies A, Ruiz G, Artés M, Gil J, Puigdollers A. Properties of superelastic nickel–titanium wires after clinical use. Materials (Basel). 2023;16(16):5604.
  4. Santoro M, Nicolay OF, Cangialosi TJ. Pseudoelasticity and thermoelasticity of nickel–titanium alloys: a clinically oriented review. Part I: Temperature transitional ranges. Am J Orthod. 2001;119(6):587–593.
  5. Aydın B, Şenışık NE, Koşkan Ö. Evaluation of the alignment efficiency of nickel–titanium and copper–nickel–titanium archwires in patients undergoing orthodontic treatment over a 12-week period: a single-center, randomized clinical trial. Korean J Orthod. 2018;48(3):153–162.
  6. Pandis N, Bourauel CP. Nickel-titanium (NiTi) arch wires: the clinical significance of superelasticity. Semin Orthod. 2010;16(4):249–257.
  7. Pathak P, Banerjee R, Duseja S, Sharma T. Newer orthodontic archwires: a review. Int J Oral Health Dent. 2022;8(1):27–30.
  8. Iijima M, Ohno H, Kawashima I, Endo K, Mizoguchi I. Mechanical behavior at different temperatures and stresses for superelastic nickel-titanium orthodontic wires. Dent Mater. 2002;18(1):88–93.
  9. Gao X, Powers JM, Sakima MT, Tantbirojn D. Influence of stress and strain rate on the mechanical properties of nickel-titanium archwires. J Biomed Mater Res. 1996;30(3):333–340.
  10. Burstone CJ, Qin B, Morton JY. Chinese NiTi wire—a new orthodontic alloy. Am J Orthod. 1985;87(6):445–452.
  11. Biermann MC, Berzins DW, Bradley TG. Comparison of the mechanical properties and surface topography of as-received and as-retrieved copper-nickel-titanium arch wires: an ex-vivo study. J Mech Behav Biomed Mater. 2022.
  12. Lee JY, Kim KH, Choi YJ, Park YG. Effect of different force magnitudes on periodontal ligament remodeling during orthodontic loading. Orthod Craniofac Res. 2019;22(4):249–256.
  13. Parvizi F, Rock WP. The load/deflection characteristics of thermally activated orthodontic archwires. Eur J Orthod. 2003;25(4):417–421.
  14. Gil FJ, Planell JA. Effect of copper addition on the superelastic behavior of Ni-Ti shape memory alloys for orthodontic applications. J Biomed Mater Res. 1999;48(5):682–688.
  15. Wilkinson PD, Dysart PS, Hood JA, Herbison GP. Load-deflection characteristics of superelastic nickel-titanium orthodontic wires. Am J Orthod. 2002;121(5):483–495.
  16. Pandis N, Polychronopoulou A, Eliades T. Alleviation of mandibular anterior crowding with copper-nickel-titanium vs nickel-titanium wires: a double-blind randomized controlled trial. Am J Orthod Dentofacial Orthop. 2009;136(2):152.e1–152.e7.
  17. Srivastava K, Chandra PK, Kamat N. Effect of fluoride mouth rinses on various orthodontic archwire alloys tested by modified bending test: an in vitro study. Indian J Dent Res. 2012;23(3):433–434.
  18. Puranitee V, Dechkunakorn S, Anuwongnukroh N, Khantachawana A, Phukaoluan A. Comparison of loading and unloading behavior of commercial and locally made copper-nickel-titanium (NiTiCu) orthodontic archwire. Adv Mater Res. 2013;746:308–314.
  19. Gatto E, Matarese G, Di Bella G, Nucera R, Borsellino C, Cordasco G. Load–deflection characteristics of superelastic and thermal nickel–titanium wires. Eur J Orthod. 2013;35(1):115–123.
  20. Pompei-Reynolds RC, Kanavakis G. Interlot variations of transition temperature range and force delivery in copper-nickel-titanium orthodontic wires. Am J Orthod Dentofacial Orthop. 2014;146(2):215–226.
  21. Major PW, Toogood RW, Badawi HM, Carey JP, Seru S. Effect of wire size on maxillary arch force/couple systems for a simulated high canine malocclusion. J Orthod. 2014;41(4):285–291.
  22. Aghili H, Yasssaei S, Ahmadabadi MN, Joshan N. Load deflection characteristics of nickel titanium initial archwires. J Dent (Tehran). 2015;12(9):695–704.
  23. Ruwiaee RA, Al-Huwaizi AF. In-vitro evaluation of load-deflection characteristics and force levels of nickel titanium orthodontic archwires. J Dent (Baghdad). 2015;27(3):159–164.
  24. Jelodar R, Shafiei F, Yalda Rezaei A. The evaluation of the fatigue and thermocycling effects on the maximum loading and unloading force of the CuNiTi wire. J Dent (Iranian). 2015;10(2):1–6.
  25. Arreghini A, Lombardo L, Mollica F, Siciliani G. Load deflection characteristics of square and rectangular archwires. Int Orthod. 2016;14(1):1–14.
  26. Rosen MA. Mechanical properties of copper-nickel-titanium archwires. 2016.
  27. Garcia FG, Barbosa JA, Basting RT. Comparative analysis of plastic deformation of NiTi and CuNiTi wires submitted to mechanical cycling. Braz Dent Sci. 2017;20(3):78–86.
  28. Pratomo HG, Mardiati E, Soemantri ES, Evangelina IA. Deflection test on different orthodontic wire materials sized 0.016 × 0.022 inches. Maj Ked Gigi Ind. 2018;4:142–147.
  29. Aydın B, Şenışık NE, Koşkan Ö. Evaluation of the alignment efficiency of nickel-titanium and copper-nickel-titanium archwires in patients undergoing orthodontic treatment over a 12-week period: a single-center, randomized controlled clinical trial. Korean J Orthod. 2018;48(3):153–162.
  30. Atik E, Gorucu-Coskuner H, Akarsu-Guven B, Taner T. A comparative assessment of clinical efficiency between premium heat-activated copper nickel-titanium and superelastic nickel-titanium archwires during initial orthodontic alignment in adolescents: a randomized clinical trial. Prog Orthod. 2019;20(1):46.
  31. Prasanna Arvind TR, Dinesh SS. Load deflection rate and properties of three different brands of single strand superelastic CuNiTi—a material study. Int J Dentistry Oral Sci. 2021;8(3):1851–1857.
  32. Mane P, Ganiger CR, Pawar R, et al. Effect of fluoride on mechanical properties of NiTi and CuNiTi orthodontic archwires: an in vitro study. Dental Press J Orthod. 2021;26(2):e212020.
  33. Mohan R, Jain RK. Comparison of load deflection characteristics of laser-treated CuNiTi archwire with other aligning orthodontic wires: an in vitro study. Int J Health Sci. 2022;6(S5):6791–6798.
  34. Babanouri N, Sarbaz M,Alamdarloo Y, Haghighat M, Ajami S. Comparison of the mechanical properties and surface topography of as-received and as-retrieved copper-nickel-titanium arch wires: an ex-vivo study. Int Orthod. 2023;21(1):100720.
  35. Iriani MT, Sayuti E, Laviana A, Mardiati E. Deflection test comparison of ISO and non-ISO copper nickel-titanium archwires: in vitro study. Int J Dental Med Res. 2025;18(3).
  36. International Organization for Standardization. ISO 15841: Dentistry—Wires for use in orthodontics. Geneva: ISO; 2014.
  37. Kusy RP, Greenberg AR. Effects of composition and cross-section on the elastic properties of orthodontic wires. Angle Orthod. 1981;51(4):325–341.
  38. Lombardo L, Marafioti M, Stefanoni F, Mollica F, Siciliani G. Load-deflection characteristics and force level of nickel-titanium initial archwires. Angle Orthod. 2012;82(3):507–521.
  39. Kusy RP, Whitley JQ. Influence of archwire and bracket dimensions on sliding mechanics. Eur J Orthod. 1999;21(2):199–208.
  40. Sabbagh H, Janjic Rankovic M, Martin D, et al. Load deflection characteristics of orthodontic Gummetal® wires in comparison with nickel–titanium wires: an in vitro study. Materials. 2024;17(2):533.
  41. Tonner RI, Waters NE. The characteristics of super-elastic Ni-Ti wires in three-point bending. Part I: the effect of temperature. Eur J Orthod. 1994;16(5):409–419.
  42. Askari H, et al. Load–deflection characteristics of superelastic nickel–titanium orthodontic wires. Dent Res J. 2016.
  43. Lombardo L, Toni G, Mazzanti V, Mollica F, Spedicato GA, Siciliani G. The mechanical behavior of as received and retrieved nickel titanium orthodontic archwires. Prog Orthod. 2019;20(1):1.
  44. Gonzaga AS, Gonzaga DS, Simplício H, Martins RP, Galvão MR, Caldas SGFR. Can we expect similar behavior among CuNiTi 35°C wires? Dental Press J Orthod. 2021;26(2):e211945.

Background: Copper–nickel–titanium (CuNiTi) archwires are widely used during orthodontic alignment because of their superelastic behaviour and favourable force delivery. However, wires with identical nominal dimensions may show substantial differences in mechanical performance. This study evaluated and compared the load–deflection characteristics of six commercially available CuNiTi archwires in 0.014-inch round and 0.014 × 0.025-inch rectangular dimensions.

Keywords : Copper–Nickel–Titanium; CuNiTi; Orthodontic Archwire; Load–Deflection; Three-Point Bending; Superelasticity; Mechanical Properties).

Paper Submission Last Date
30 - November - 2026

SUBMIT YOUR PAPER CALL FOR PAPERS
Video Explanation for Published paper

Never miss an update from Papermashup

Get notified about the latest tutorials and downloads.

Subscribe by Email

Get alerts directly into your inbox after each post and stay updated.
Subscribe
OR

Subscribe by RSS

Add our RSS to your feedreader to get regular updates from us.
Subscribe